Guides

Is a Rubber Bullet Trap a Fire Risk?

Yes, a rubber bullet trap can catch fire. The US Department of Defense reports rubber-trap fires that caused significant damage at several of its indoor ranges, mainly through poor maintenance and tracer rounds (UFC 4-179-02). The Estonian Centre for Defence Investments (RKIK) bans tracers in its indoor ranges because of the fire risk. BulletTrap Baltic

Is a Rubber Bullet Trap a Fire Risk? Read More »

German Schießstandrichtlinien: What They Require From a Bullet Trap and Wall Lining

The German Schießstandrichtlinien (23 July 2012, BAnz AT 23.10.2012 B2) require indoor ranges to clad hard surfaces facing the shooter with at least 2.4 cm of softwood or an equivalent agreed with the range expert, to line walls and ceilings so rounds striking at 25°–90° do not come back, to face the wall behind the

German Schießstandrichtlinien: What They Require From a Bullet Trap and Wall Lining Read More »

Polish Indoor Shooting Range Rules (Dz.U. 2022 poz. 848): Walls, Ceiling and Bullet Trap

Dz.U. 2022 poz. 848 is the Polish Interior Ministry regulation of 31 March 2022 for the indoor ranges of the Police, the Border Guard and the State Protection Service; it does not apply to civilian or club ranges. In force since 5 May 2022, it requires a safety coefficient against perforation of at least 2.5

Polish Indoor Shooting Range Rules (Dz.U. 2022 poz. 848): Walls, Ceiling and Bullet Trap Read More »